Sensors and accuracy specifications
Parameter | Range | Accuracy |
CO2 | 0 to 5000 ppm | ± 75 ppm @ 400-1000 ppm ± 40 ppm + 5% m.v. @ 1001 ppm – 2000 ppm |
(Particulate Matter)
PM1
PM2.5 | 0 to 1000 μg/m3 | PM1 accuracy ±[5 μg/m³ + 5 % m.v.] at 0 to 100 μg/m³ ±10 % m.v. at 100 to 1000 μg/m³ PM2.5 accuracy 0-75 μg/m3 ≤ 5 μg/m³ |
PM10 | 0 to 1000 μg/m3 | ±25 μg/m³ at 0 to 100 μg/m³ ±25 % m.v. at 100 to 1000 μg/m³ |
TVOC (ppm) | 0 to 3 ppm | 15% of the measured value |
CH2O | 0 to 1 ppm | ±0.02 ppm or ±20% of the measured value, whichever is larger. |
Temperature | -40 to +125C | ± 0.5 C |
Relative Humidity | 0 to 100 %RH | ± 2 %RH |
Light Intensity | 0 - 60000 lux | ±10% |
Background Noise Level | 30 - 100 dB | ±2dB |
Sampling Interval
Every 5 minutes by default
On-Event data if under alarm (every 1 minute)
LED Status Indicator
LED configuration by default are based on the Cairo Consensus Guidelines for IVF Laboratories
Customized LED configurations are available by request. If needed, please consult ViGIE Team, we'd be happy to help.
Requirements
Power Socket
Ethernet Port (PoE Version available)
WI-FI connection is also available
Dimensions
More details
HealthCube IAQ Installation Guide